How to install Kerui gas alarm system for kitchen
Important note: If you add an automatic shut-off solenoid valve (interlock system), the gas valve part must be installed and tested by a licensed gas engineer; do NOT connect gas pipes yourself机电工程署.
1. Choose the correct detector (critical)
- Natural gas (methane, piped town gas): lighter than air → Install within 30 cm / 12 inches below the ceiling
- LPG / Propane / bottled gas: heavier than air → Install within 30 cm / 12 inches above the floor
Buy a detector calibrated for your gas type. A wrong sensor height means it may never detect leaks.
2. Rules for picking the mounting spot
✅ Good location
- Same room as your gas stove/gas meter
- Horizontal distance: 1.5–4 m from the gas hob (avoid being too close to prevent false alarms from cooking smoke/steam)
- Open air flow, not blocked by cabinets or curtains
❌ Never install here
- Directly above the stove / range hood (high heat, oil fume damages sensor)
- Near windows, exhaust fans, air-condition vents (draught blows gas away)
- Inside closed cabinets, wet areas (sink), high-temperature spots
- Peaks of vaulted ceilings (stagnant air pockets)
3. Tools you need
Drill + wall plugs, screwdriver, pencil, level, dry cloth. Most home alarms are plug-in AC 220V / 110V, some are wired or battery backup.
4. Step-by-step installation (standalone plug-in alarm)
- Mark the wall position following the height rule for your gas. Check no hidden wires/pipes behind the wall.
- Drill holes, insert wall anchors, fix the mounting bracket with screws.
- Clip the gas detector onto the bracket.
- Plug into a permanent power socket (do not use a switchable socket you can accidentally turn off).
- Power on: It will go through a warm-up countdown (usually 2–3 minutes, flashing LED) before entering monitoring mode.
- Press the TEST button to check loud sound and flashing alarm light work normally.
5. If you install the linked automatic shut-off system (recommended)
This system = gas detector + solenoid shut-off valve on the gas supply pipe:
- A certified gas fitter installs the solenoid valve on the main gas pipe.
- Wire the signal cable from detector to the solenoid valve (follow the manual wiring diagram).
- After all wiring, power on and test: trigger the test alarm, the valve should automatically cut off gas supply.
- After test, manually reset the solenoid valve to resume gas flow.
6. Maintenance & emergency rules
- Test with the test button once per month.
- Wipe dust/oil on sensor with a dry cloth; no alcohol or spray cleaner.
- Replace the whole unit every 5 years (sensor has a fixed service life)深圳市住房....
- When alarm sounds:
- Turn off the main gas valve
- Open doors/windows to ventilate
- Do NOT touch light switches, phones, plugs, lighters
- Evacuate and call the gas supplier
7. Extra tips
- If you use both natural gas and LPG, fit two separate detectors at their correct heights.
- Smart models can connect to Wi‑Fi hubs and send phone alerts.
- Always follow your local gas safety code and the product manual first